ในการผลิตยา, ซีไอพี (ทำความสะอาดในสถานที่) และ จิบ (Sterilization-in-Place) serve complementary roles in maintaining product safety. พูดง่ายๆ, CIP removes product and process residues from equipment surfaces without disassembly, while SIP uses pressurized steam to sterilize those already-cleaned surfaces. CIP employs circulating water and detergents to chemically clean pipes, tanks and vessels, achieving validated removal of soils to health-based limits. SIP follows by applying saturated steam (typically above 121 °C) to kill any remaining microorganisms. ในสาระสำคัญ, CIP cleans, and SIP sterilizes; neither process alone accomplishes the other’s job. ด้วยเหตุนี้, in sterile or aseptic processes CIP is normally performed before SIP to avoid any residues shielding microorganisms during the sterilization step.

CIP systems spray heated cleaning solutions through nozzles and spray balls to wet all product-contact surfaces, then rinse them clean. นี้ automated cleaning sequence typically includes pre-rinsing, alkaline detergent washing, intermediate rinses, optional acid wash, and a final rinse. Four key parameters – temperature, chemical concentration, flow rate and time – govern CIP efficacy. CIP equipment usually consists of chemical preparation and recovery tanks, supply and return pumps, เมตรการไหล, sanitary valves and instrumentation, all controlled by a PLC or control panel. By circulating cleaning agents through the fixed pipeline and process equipment (รถถัง, เครื่องผสม, ตัวกรอง, ฯลฯ), CIP systems clean the interior surfaces without having to take the equipment apart. This not only reduces manual labor and downtime, but also minimizes the risk of contamination from human intervention. ที่สำคัญ., อย่างไรก็ตาม, CIP is a cleaning process only – it does not achieve sterility.

CIP vs SIP in pharmaceutical manufacturing, showing clean-in-place spray cleaning and steam-in-place sterilization in stainless steel process equipment.

 

What Is CIP (ทำความสะอาดในสถานที่) in Pharmaceutical Manufacturing?

Definition and Purpose: ซีไอพี (ทำความสะอาดในสถานที่) is a method of cleaning the interior product-contact surfaces of processing equipment in situ, without dismantling the system. During a CIP cycle, clean water and cleaning solutions (ผงซักฟอก, ด่าง, กรด, sanitizers, ฯลฯ) are pumped through the equipment (รถถัง, ท่อ, วาล์ว) in a pre-defined sequence of steps. The goal is to dissolve and flush out residues from the previous batch – including API, สารเพิ่มปริมาณ, สารทำความสะอาด, and biofilms – until the system is visibly clean and meets validated residue limits. ที่สำคัญ., CIP is focused on ทำความสะอาด, not sterilization: while a CIP step may include a sanitizing rinse, it is not sufficient by itself to guarantee a sterile state.

Typical CIP Cleaning Stages: A standard CIP cycle usually consists of:

  • Pre-rinse:Flushing with water to remove loose product or debris.
  • Detergent Wash:Circulating an alkaline or acidic detergent solution at elevated temperature and turbulence to dissolve adhered product and soils.
  • Intermediate Rinse (ถ้าจำเป็น):เช่น, an acid wash to remove hard water scale if an alkaline wash was used.
  • Final Rinse:Circulating high-purity water to remove residual cleaning agents and any loosened soil.
  • การฆ่าเชื้อ (ไม่จำเป็น):A final rinse with a sanitizer (E.G. hot water, peracetic acid) or another agent to reduce microbial load if required.

Each stage has controlled parameters: อุณหภูมิ, chemical concentration, flow rate/velocity, and contact time are all specified and monitored. ตัวอย่างเช่น, higher temperatures and sufficient flow (usually above a critical velocity) improve cleaning efficiency by increasing solubility and ensuring turbulence.

Key CIP System Components: A CIP system typically includes storage tanks for fresh and spent cleaning fluids, dosing/heat-exchange systems, ปั๊ม, flow meters and valves to circulate cleaning solutions, spray balls or jet heads inside tanks, and instrumentation (conductivity, อุณหภูมิ, flow sensors) to monitor each step. The system is usually automated via a control panel to execute set “recipes” of rinse, wash, and rinse. A well-designed CIP system follows hygienic design principles (smooth pipes, ไม่มีขาตาย, drains) so that cleaning solutions can reach all wetted surfaces and drain completely.

 

What Is SIP (Sterilization-in-Place) in Pharmaceutical Manufacturing?

Definition and Purpose: จิบ (Sterilize-In-Place), also called Steam-In-Place (when using steam), is a method of ฆ่าเชื้อ the internal surfaces of equipment in situ, without disassembly. In pharmaceutical operations, SIP is used after cleaning to inactivate (destroy) any remaining microorganisms on product-contact surfaces. โดยทั่วไป, SIP involves circulating saturated clean steam through the system at a specified temperature and pressure, holding it long enough to achieve the required sterility assurance level. The main aim of SIP is microbial kill - ตัวอย่างเช่น, achieving a sterility assurance level (สล) of 10^-6 for aseptic processes.

Common SIP Sterilization Stages: A typical SIP cycle includes:

  • Steam Admission:Introducing clean, dry saturated steam into the equipment while venting air. Air removal (E.G. via condensate traps or steam mixing) is critical to ensure uniform heat distribution.
  • Heating Phase:Raising the system’s internal temperature to the target sterilization temperature. Steam condenses on surfaces to release latent heat, driving heat penetration.
  • Sterilization Hold (อยู่):Maintaining the equipment at the target sterilization temperature (often between 121°C and 135°C for wet heat) for a validated time period. The exact temperature-time combination is chosen based on worst-case locations.
  • Cooling and Venting:After the hold, steam is vented or withdrawn, and any condensate is drained. The system may be cooled with sterile air or allowed to cool naturally to avoid overheated surfaces.
  • Sterile Hold:Once cooled, the system should remain closed and sealed to maintain sterility until the next use.

Key SIP Parameters: Critical factors in SIP are steam quality และ อุณหภูมิ. The steam must be saturated (no liquid water droplets) and “clean” (ปราศจากน้ำมัน, filtered) to avoid contamination. The pressure is usually set just above what is needed to maintain the target temperature (ตัวอย่างเช่น, ~2.0 bar for 121°C). ที่ temperature distribution must be uniform; cold spots (E.G. dead legs, กระเป๋า) are avoided through design and by possibly using vacuum or pulsation to purge air. Exposure time (hold time) at temperature must be long enough to achieve microbial kill throughout the equipment. บ่อยครั้ง, validation will use biological indicators and multiple thermocouples at the worst-case points to confirm this.

 

Key Differences Between CIP and SIP

CIP and SIP are often used together, but they are fundamentally different processes. The table below summarizes their main differences:

ด้าน ซีไอพี (ทำความสะอาดในสถานที่) จิบ (Sterilization-in-Place)
ชื่อเต็ม ทำความสะอาดในสถานที่ Sterilization-in-Place (often using steam)
วัตถุประสงค์หลัก Remove product and chemical residues Destroy viable microorganisms (sterilize equipment)
Primary Medium Recirculated water and detergents Hot saturated steam (often 100–130 °C)
Target Contamination Product soils, dirt, cleaning agent residues Microbial contamination (แบคทีเรีย, spores, viruses)
Validation Focus Cleaning effectiveness (residue limits, rinse/swab tests) Sterility (temperature distribution, biological indicators, F₀ value)
กรณีการใช้งานทั่วไป Non-sterile processes (รถถัง, pipelines, non-sterile equipment) Sterile processes (aseptic lines, closed reactors, filling skids)

กล่าวอีกนัยหนึ่ง, CIP’s job is to make equipment visibly clean and chemically free of residue, while SIP’s job is to make it microbiologically sterile. CIP leaves behind no harmful dirt or detergents beyond validated limits. SIP leaves behind no viable organisms, achieving a high sterility assurance level (often 10^-6) on equipment surfaces. Because they address different hazards, both processes are often required: ตัวอย่างเช่น, an aseptic filling line usually uses CIP to clean between product batches and then SIP to sterilize the filling manifold and tank before filling.

 

How CIP and SIP Work Together

ในทางปฏิบัติ, pharmaceutical manufacturing lines that require sterility will implement CIP followed by SIP as a coordinated sequence. First a CIP cycle removes all product residues to health-based limits; แล้ว, after draining, a SIP cycle exposes the system to sterile steam. Automation can lock out the SIP step until the CIP pass is confirmed successful. This ensures steam sterilization is not attempted on a dirty system (residues could insulate microbes from heat). In a well-designed process, both cycles are validated and run routinely between production runs.

ตัวอย่างเช่น, a pharmaceutical tank may be cleaned by CIP (washing with caustic and rinsing with purified water) and then sterilized by SIP (steam injection at 121 °C for a validated hold time). Different equipment may require different approaches: an aseptic powder line might have a combined CIP/SIP skid, while an aseptic liquid filler often includes integrated steam jackets. ที่สำคัญ., CIP precedes SIP but is not required for every piece of equipment. Non-sterile process equipment (like many tablet presses or capsule filling machines) often only use CIP or even manual cleaning, whereas critical sterile equipment (like fermenters, ไลโอฟิไลเซอร์, or filling tunnels) will use both CIP and SIP.

 

Which Pharmaceutical Equipment Requires CIP or SIP?

Not all pharma equipment has built-in CIP/SIP capabilities. โดยทั่วไป, process equipment – such as tanks, เครื่องปฏิกรณ์, ท่อ, heat exchangers, and filtration skids – is CIP-cleaned and often SIP-sterilized. เช่น, large mixing vessels or buffer tanks in a sterile production area will typically be connected to a CIP/SIP loop. ในทางตรงกันข้าม, เครื่องบรรจุภัณฑ์ เหมือนการกดแท็บเล็ต, capsule fillers or blister machines are usually cleaned by Clean-Out-of-Place (ตำรวจ) วิธีการ (manual disassembly, แปรง, foams) rather than CIP, because their multi-part mechanical designs make full CIP circuits impractical. If such equipment must support aseptic processing, it may be installed in a cleanroom and sterilized by separate means (E.G. hydrogen peroxide), but typically they do not run internal CIP/SIP cycles.

As an example, จินหลู่แพ็คกิ้ง เครื่องบรรจุแคปซูลอัตโนมัติ และ แท็บเล็ตความเร็วสูง เป็น GMP-compliant equipment ออกแบบมาเพื่อทำความสะอาดง่าย (with polished surfaces and 316แอล สแตนเลส), but they rely on validation per batch rather than an internal SIP system. ในทางกลับกัน, dedicated aseptic fillers or lyophilizer tanks often incorporate full CIP/SIP skids. When designing a new line, engineers must consider which components will use CIP, which will use SIP, and which will be cleaned manually, all based on contamination risk and process requirements.

 

CIP and SIP Validation: ข้อกำหนด GMP

Both CIP and SIP must be validated and documented according to GMP. กฎระเบียบ GMP (เช่น อย 21 ซีเอฟอาร์ 211.67 และ 211.113) mandate that equipment be cleaned and, when needed, sterilized by written procedures. ในทางปฏิบัติ, นี่หมายความว่า:

  • CIP Validation:A cleaning cycle must consistently remove residues to below a defined limit (often a health-based MACO/HBEL rather than an arbitrary percentage of last product). Validation involves testing rinse or swab samples for drug/solvent/cleaning-agent residues, visually inspecting cleanliness, and in some cases microbiological checks. แนวปฏิบัติด้านกฎระเบียบ (อย, ภาคผนวกของสหภาพยุโรป 15, EMA HBEL) require that acceptance criteria be scientifically justified. ตัวอย่างเช่น, EMA and Health Canada guidelines now require limits based on toxicological risk (PDE/PDE-derived MACO) rather than legacy defaults.
  • SIP Validation:A sterilization cycle must prove lethality to the required sterility level. This entails conducting temperature mapping (to identify cold spots) and placing biological indicators (spore strips) at worst-case locations. The cycle is typically characterized by its F₀ or D-value to demonstrate a 6-log kill of spores. อย 21 ซีเอฟอาร์ 211.113(ข) explicitly requires validation of any sterilization process for sterile products. Modern guidelines (EU GMP Annex 1, ISO 17665) expect documented proof that every point in the system reached the target sterilization temperature for the validated time. Clean steam quality (particle and microbial limits) must also meet pharmacopeial standards.

Each CIP and SIP system is treated as a critical process: it should have a defined scope, เกณฑ์การยอมรับ, and requalification schedule. Routine verification (E.G. conductivity or TOC monitoring of rinse water) ensures ongoing control. In inspections, regulators often focus on issues like inadequate cleaning before SIP or poor steam penetration. By properly validating CIP (ensuring no cross-contamination) and SIP (ensuring sterility), manufacturers comply with the spirit of cGMP rules without claiming that “every piece of equipment must have CIP/SIP” – rather, equipment must be cleaned and sterilized as appropriate.

 

Choosing CIP, SIP or Both

Deciding whether to implement CIP, จิบ, or an integrated CIP/SIP system depends on the product and process. ปัจจัยสำคัญได้แก่:

  • Product Sterility Requirement:If the product is terminally sterilized (E.G. autoclaved in final container) or is a non-sterile oral formulation, CIP alone may suffice to prevent cross-contamination. If the product is filled aseptically or is a sterile pharmaceutical/biologic, both CIP and SIP are typically required to control particulate and microbial contamination.
  • ความเสี่ยงจากการปนเปื้อนข้าม:For multi-product facilities, CIP is essential to remove allergens or APIs between batches. SIP may be added if any microbial risk remains after cleaning.
  • Equipment Design and Cost:CIP/SIP skids add complexity and cost. For large fermenters or buffer tanks, the investment may be justified. For small bench equipment or basic mixers, a simpler COP procedure may be adequate.
  • Production Scale and Frequency:High-throughput or continuous lines benefit from automated CIP to minimize downtime. If the line rarely changes products, manual cleaning might be more cost-effective. SIP typically adds time and requires steam infrastructure, so its ROI must be weighed against sterility needs.
  • Utilities and Integration:Implementing CIP/SIP requires utilities (clean steam, น้ำบริสุทธิ์, เครื่องทำความร้อน) and control logic. Integrating CIP and SIP can improve compliance and data integrity (ตัวอย่างเช่น, interlocks ensure an SIP cycle only runs after CIP).

ในที่สุด, the choice is driven by a GMP risk assessment: evaluate the contamination hazards and verify that cleaning or sterilization methods mitigate them. For many sterile pharma lines, the answer is an integrated CIP/SIP system – as one industry guide summarizes, “CIP must prove cleaning to a health-based limit… SIP must prove lethality at every cold spot with saturated steam and biological indicators”. In non-sterile lines, simpler CIP or manual cleaning may be sufficient.

 

Common CIP and SIP Mistakes

Even experienced facilities can stumble on CIP/SIP execution. Some typical pitfalls include:

  • Assuming CIP Sterilizes:CIP cleans away soils but does ไม่ ensure sterility. Failing to run a proper SIP (or alternative sterilization) after CIP can leave dangerous microbes alive.
  • Dead Legs and Poor Drainage:Sanitary design is critical. Unaddressed dead legs or horizontal runs can harbor residues and microbes, making cleaning/sterilization ineffective. Every branch of piping should self-drain and have minimal stagnant zones.
  • Ignoring Steam Condensate:In SIP, steam will condense, especially in low spots or cool areas. Condensate cools those areas and can lead to “cold spots” that are not sterilized. Proper steam trap placement and process heating up/down sequences are needed.
  • Inadequate Cycle Validation:Skipping proper validation means you don’t know if the process works. For CIP, it’s a mistake not to sample worst-case locations for residue. For SIP, failing to do a thorough temperature distribution test can leave parts of a vessel unvalidated.
  • Combining Protocols Unnecessarily:Treating CIP and SIP as one generic “clean cycle” without separate acceptance criteria can confuse auditors. Maintain distinct protocols and logs for CIP vs SIP.

Avoiding these errors requires good engineering and procedures. ตัวอย่างเช่น, industry experts highlight that การออกแบบที่ถูกสุขลักษณะ (พื้นผิวเรียบ 316L, properly sloped drain, certified valves) is a prerequisite for effective CIP/SIP. Regular training and documentation help operators follow the validated procedures precisely.

 

บทสรุปและขั้นตอนต่อไป

โดยสรุป, CIP and SIP are sequential and complementary steps in pharmaceutical equipment cleaning. CIP removes soils and residues to prepare equipment for the sterile state, and SIP then ensures that all remaining microorganisms are inactivated. Neither process replaces the other – both must be applied as appropriate per GMP to protect product quality.

ที่ จินลูบรรจุหีบห่อ, we specialize in pharmaceutical production and packaging equipment built for rigorous cleaning protocols. Our capsule filling machines, แท็บเล็ตกด, and turnkey aseptic lines use hygienic design and premium stainless steel to facilitate effective cleaning and sterilization. Whether you need GMP-compliant mixing tanks with CIP/SIP capability or reliable high-speed fillers and packers, we can advise on the right solutions. ติดต่อทีมงานของเรา to discuss how to integrate proper CIP and SIP processes into your production and ensure compliance with all GMP requirements.

 

 

คำถามที่พบบ่อยเกี่ยวกับ CIP vs SIP in Pharmaceutical Manufacturing

What is the main difference between CIP and SIP?

ซีไอพี (ทำความสะอาดในสถานที่) is a cleaning process that removes soils and residues from equipment using detergents and rinses. จิบ (Sterilization-in-Place) follows by applying high-temperature steam to kill any microorganisms. CIP achieves cleanliness; SIP achieves sterility.

Can CIP sterilize pharmaceutical equipment?

เลขที่. CIP is designed to clean, not to sterilize. It removes visible dirt, สารตกค้างของผลิตภัณฑ์, and helps reduce the microbial load, but it does not ensure a sterile condition. If sterility is required, a dedicated SIP cycle (or other sterilization) is needed after CIP.

Is a CIP cycle always required before SIP?

In most cases where both are used, ใช่. Performing CIP first removes soils that could shield microbes during sterilization. อย่างไรก็ตาม, not all processes require SIP, so CIP may stand alone for non-sterile lines.

Can CIP be used instead of manual cleaning (ตำรวจ) for all equipment?

Only if the equipment has a sanitary design that supports CIP. รถถัง, reactors and closed piping are CIP-friendly. หลายเครื่อง (E.G. แท็บเล็ตกด, ฟิลเลอร์แคปซูล, เครื่องบรรจุภัณฑ์) require disassembly and cleaning of parts (ตำรวจ) because their internals cannot be cleaned by simple recirculation.

What sterilization conditions are typical for SIP?

Common SIP cycles use saturated steam at 121 °C (or sometimes 134 °C) for a specified hold time (often 15–30 minutes). The exact temperature and time depend on the system design and must be validated. Regulatory expectations (like EU GMP Annex 1) demand that every point in the system be shown to reach the target temperature for the full duration.

How do you validate a CIP system?

Cleaning validation typically involves establishing a worst-case residue (E.G. the hardest-to-clean drug or highest potency API) and demonstrating its removal. This is done by sampling (swabs or rinse water) and analyzing for residues, as well as visually inspecting. Acceptance limits are usually based on toxicological thresholds (MACO/HBEL).

What does F₀ mean in SIP validation?

F₀ is a measure of sterilization lethality (the equivalent time at 121 °C). SIP validation often uses F₀ calculations or D-values of spores to quantify that the cycle provides sufficient kill. ในทางปฏิบัติ, many plants just ensure the validated time/temperature is reached everywhere.

Is SIP required by GMP?

No regulation explicitly says “you must use SIP,” but GMP requires that sterile products be manufactured in a way that ensures microbial control. ในความเป็นจริง, if your process involves sterile drug products, จิบ (or other sterilization) becomes a necessary part of your validated contamination control strategy (as per FDA 211.113 และภาคผนวกของสหภาพยุโรป 1).

How does CIP differ from COP (Clean-Out-of-Place)?

CIP cleans equipment in place without disassembly. COP means equipment is taken apart and cleaned manually or in a washer. CIP is faster and less labor-intensive for suitable equipment, but not all machines can be CIP-cleaned.

What are the main challenges in CIP and SIP system design?

Key challenges include ensuring complete coverage (ไม่มีขาตาย), uniform heating (no cold spots in SIP), and consistent drainability. Other issues: choosing materials compatible with aggressive cleaners and steam; calibrating sensors for high accuracy; and coordinating utilities (enough steam and clean water capacity). In integrated lines, making sure sequence controls and interlocks (CIP complete before SIP) are reliable is also crucial. These challenges must be addressed in engineering design and documented in qualification protocols.

 

 

อ้างอิง:
1.ปริมาณ EudraLex 4, ภาคผนวก 1 — Manufacture of Sterile Medicinal Products —— คณะกรรมาธิการยุโรป
2.21 ซีเอฟอาร์ § 211.67 – Equipment cleaning and maintenance. —— เรา. สำนักงานคณะกรรมการอาหารและยา
3.WHO Good Manufacturing Practices for Sterile Pharmaceutical Products —— WHO — TRS 1044, ภาคผนวก 2
4.แนะนำ: วงจรการตรวจสอบความถูกต้องของการทำความสะอาด – แอปพลิเคชัน, วิธีการ, & การควบคุม —— ไอเอสพีอี
5.Guide to Inspections: การตรวจสอบความถูกต้องของกระบวนการทำความสะอาด —— อย
6.Sterilization and Cleaning in Place —— เจ-เวที

แบ่งปันบทความนี้:
รูปภาพของ เพตตี้ ฟู
เพตตี้ ฟู

เพตตี้ ฟู, ผู้ก่อตั้ง Jinlupacking, นำมาซึ่ง 20 ความเชี่ยวชาญหลายปีในภาคส่วนเครื่องจักรยา. ภายใต้การนำของเขา, Jinlu เติบโตเป็นซัพพลายเออร์ที่เชื่อถือได้โดยผสมผสานการออกแบบ, การผลิต, และการขาย. Petty มีความกระตือรือร้นในการแบ่งปันความรู้เชิงลึกในอุตสาหกรรมของเขา เพื่อช่วยลูกค้าจัดการกับความซับซ้อนของบรรจุภัณฑ์ยา, รับรองว่าพวกเขาจะได้รับไม่ใช่แค่อุปกรณ์เท่านั้น, แต่เป็นพันธมิตรด้านบริการแบบครบวงจรที่แท้จริงซึ่งปรับให้เหมาะกับเป้าหมายการผลิต.

สารบัญ

ส่งคำถามของคุณ

ทิ้งคำตอบไว้

ที่อยู่อีเมลของคุณจะไม่ถูกเผยแพร่. ช่องที่ต้องกรอกถูกทำเครื่องหมายไว้ *

รับใบเสนอราคาฟรี

*เราเคารพการรักษาความลับของคุณและข้อมูลทั้งหมดได้รับการคุ้มครอง. ข้อมูลส่วนบุคคลของคุณจะถูกนำมาใช้และประมวลผลสำหรับโซลูชัน JL เท่านั้น.